Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity Inlet Flow Rate | 60 L/Hour |
| Usage/Application | Industries |
| Automation Grade | Fully Automatic |
| Material | Stainless Steel |
| Efficiency | 5/10/20/30/40/60 l/hour |
| Conductivity | < 5 µS/cm** |
Perfect for washers, analyzers, autoclaves, environmental chambers, water baths, HLP demineralizers, as well as, through developing a proper network, supplying several laboratory rooms and floors.
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity Inlet Flow Rate | 60 L/Hour |
| Capacity (LPH) | 4 to 30 liters per hour (LPH) |
| Usage/Application | Industries |
| Automation Grade | Fully Automatic |
| Material | Stainless Steel |
| Water Source | Industrial Effluent |
The Technical Plus demineralizers have been designed for laboratories that need water in the 0,06 µS/cm to 15-20 µS/cm range. Thanks to the conductivity regulation, the user can decide on the quality of the water desired. This proces allows optimisation of operating costs. Technical Plus systems are an excellent source of water for autoclaves, dishwashers, analysers, climatic cabinets, for the preparation of reagents, buffers, pH solutions as well as for chemical analysis and synthesis.
Purification stages:
•external pre-filter 5 µm •integrated module A: 1 µm mechanical filtration, activated carbon cleaning and softening. •reverse osmosis column; the contaminated part of the water is routed to the drain; purified water is pumped under pressure from the module into the tank. comes with a ion-ex cartridgeand conductivity control
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity (LPH) | 500 LPH |
| Usage/Application | Industries |
| Automation Grade | Fully Automatic |
| Material | Stainless Steel |
| Water purification levels: | demineralization on an spectrally clean ion-exchange TOC bed, UV lamp 254 nm. |
| Technical specification: | Automatic and unattended system operation , System equipped with a recirculation pump . |
| Dimensions: | 235x470x570 mm |
| Required connections: | Pressure min. 2 bar , 230V socket , Purified water fits the ISO 3696: 1999, the ASTM |
ULTRA devices provide ultrapure water that fits the PN-EN ISO 3696:1999 standard for the first purity class and EP. System is fed by an external source of initially purified water that fits the requirements for type 2 or 3 purity class, according to PN-EN ISO 3696:1999. Cleaning module is a fully automated and unattended system, equipped by default with an automatic diagnostic apparatus.
Purification stages:
- desalting on a spectral-pure mixed
ion exchange biofilter TOC
- UV lamp
- UF ultrafiltration module (option)
- cascade microfiltration capsule 0.45/0.2 µm
Purified water parameters:
TOC: < 5 ppb
Bacteria: < 1cfu/ml
Particles: > 0,2μm < 1/ml
Endotoxins: (pyrogens) < 0,001 EU/ml*
Rnases: < 0,01 ng/ml*
Dnases: < 4 pg/µl*
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity Inlet Flow Rate | 60 L/Hour |
| Usage/Application | Industries |
| Automation Grade | Fully Automatic |
| Material | Stainless Steel |
| Water Source | Industrial Effluent |
HLP demineralizers use tap water and fit every modern laboratory's requirements in areas of supplying with purified water for instrumental and analytical purposes. Conductivity of obtained water does not exceed 0,06 µS/cm, so it is applicable for PN-EN ISO 3696:1999, ASTM, CLSI, FP IX standards. Water may also be used for AAS, ICP/MS, IC, HPLC, GC instrumental analyses. In addition, our demineralizers are equipped with a microprocessor control and measurement system.
Application:
•preparation of buffers, solutions, chemical and biochemical reagents; • supply for autoclaves, clinical analysers and other laboratory equipment
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity Inlet Flow Rate | 60 L/Hour |
| Usage/Application | Industries |
| Automation Grade | Fully Automatic |
| Material | Stainless Steel |
| Dimensions (SxGxW): | 235x470x570 mm |
| Tank 10l: | height: 390 mm, diameter: 250 mm |
| Functions monitoring the device: | color display screen with a Touch Panel, clock displaying date and time. maintenance dates preview. |
SPRING demineralizers are devices fed by tap water, with a richer equipment and an advanced automatics. Same as the HLP demineralizers, SPRING systems produce water of a 0.055 µS/cm conductivity, fitting the PN-EN ISO 3696:1999, ASTM, CLSI, EP standards. These devices are dedicated for more demanding users by having an extended automatics, that allows the user to: monitor the disposable materials performance process, backup data, adjust alarm levels for the feed water, the water processed by the reverse osmosis, and the ultrapure water, control the automatic membrane rinsing, and the ultrapure water recirculation function. Systems also have safety protections for a comfortable device performance.
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity Inlet Flow Rate | 60 L/Hour |
| Usage/Application | Industries |
| Automation Grade | Fully Automatic |
| Material | Stainless Steel |
| Purified water parameters: | Purified water fits the PN-EN ISO 3696: 1999, the ASTM, and the CLSI standards for the first purity |
| Required connections in the installation place: | cold tap water connection ½” or ¾”, drainage, 230 V power socjet. |
| Dimensions: | 275x470x570 mm . |
| Tank 10l : | h. 390 mm, Ø 250 mm |
| Automatic pump shutdown when : | the feed water pressure is too low (lack of feed water) – low pressure sensor |